Two wire start – close a no voltage two wire circuit to start the engine.Auto Timed – Starting in Auto mode a start and run time can be programmed to start daily or use 16 different start event times.

#1960 lister diesel generator manual

Manual Start – Push the manual button then the Start Button.

#1960 lister diesel generator generator

The Generator Control Panel has three different methods in which it can start a generator set: If the pressure exceeds or drops below operator defined levels the controller will stop the engine to protect pipelines and pumps. The generator control panel is also configured to read a pressure transducer which is supplied where required which can monitor the water pressure in the delivery line of a pump adding another level of protection to the system. This feature is critical when powering electric motors controlled by electronic motor controllers which look for immediate accurate voltage. This also works in the reverse when the engine receives a stop signal the power is immediately switched off to the output and the engine allowed to settle back down before actually stopping. In addition to this the control panel monitors the voltage level both high and low, Hz or cycles of the alternator and the load being put on the set, if anything goes wrong the controller will pick it up.Īn additional important feature on the panel is the start delay contactor which allows the engine to start and settle into smooth operation before turning on the power to whatever is being driven. It features all the engine protection that is expected of a modern control panel monitoring Oil Pressure, Engine cooling temperature whether the engine is air or water, battery charge voltage and over speed. For example bore pumps where a dedicated line shaft pump is an expensive proposition when compared with an electric submersible. It’d features were initially designed to accommodate the requirements of generators being used in irrigation systems where direct diesel power was not convenient or financially viable. Again, many thanks for the help and encouragement.The Generator control panel has been designed to meet the needs of most generator applications without being too technical or requiring a technician to program it. But the only thing which seems to run between the generator an xfer switch is the AC wiring.īears further investigation. It definitely used to work when one initiated the engine start through the "set exercise" button on the panel. Curious though, I haven't been able to pinpoint the way in which the transfer switch tells the generator to run. Repeat the procedure if the generator fails to build voltage. Hold the F- lead by the insulated portion of the lead wire, touch F- to the negative pole of the battery for about 5 to 10 seconds, then remove. Connect F+ to the positive pole of the battery. I have not yet tried to see if simulating a power loss will cause the generator to start to run and transfer load. Also check to be sure there is no path to ground. I do now have an issue whereby the ASCO switch cannot initiate an exercise routine. I plan to clean up some more wiring, maybe pull the starter relay off the unit and bang it around a little, maybe that goes away. she's running! I still have an issue where the unit doesn't always start, sometimes only running the starter for just a quick second before then retrying. I spent some time with the generator yesterday, blew out nesting with a compressor, removed some dead mice (and some living), found some corrosion on a plug wire at one of the coils, and.











1960 lister diesel generator